Functional IgG Autoantibodies against Autonomic Nervous System Receptors in Symptomatic Women with Silicone Breast Implants
Talalai E, Gorobets D, Halpert G, et al. Cells 2023;12(11):1510.
Animals
Mice
Behavioral tests
2
Settings we look for
1 of 7 missing
Each step is a sentence from the paper’s Methods, word for word. This page covers the behavioral tests this site tracks, so the paper may have run others.
The test records were read once by AI and checked by code. No person has reviewed them yet. Code placed each sentence under its test from those records. How records are made
Not in the Methods: Illumination.
| Setting | Value | Paper’s words |
|---|---|---|
| Arena size |
| “a standardized arena of 40 × 40 cm” |
| Session duration |
| “Each mouse was placed individually for 6–10 min in the square black plastic chamber” |
| Not in the Methods | Illumination | |
| Other settings in the paper | ||
| Placed in the experimental room | Prior to the test one hour | “all the animals were placed in the experimental room one hour prior to the test” |
| Apparatus was cleaned | Between sessions 70% ethanol | “The apparatus was cleaned with 70% ethanol between sessions” |
| Made from | inert plastic | “made from inert plastic” |
| Chamber | square black plastic | “in the square black plastic chamber” |
| Placed | individually | “Each mouse was placed individually” |
| Habituation | day 2 | “day 2—habituation” |
| Open field test first run | First run day 3 | “day 3—open field test first run” |
| Open field second run | Second run day 5 | “day 5—open field second run” |
| After the injection | Day 3 two days | “in the open field paradigm, two days after the injection (Day 3)” |
| After the injection | Day 5 four days | “conducting the behavioral paradigm four days after the injection (Day 5)” |
| Apparatus | ||
| Standardized arena | Maze Engineers, Skokie, IL, USA | “a standardized arena of 40 × 40 cm made from inert plastic (Maze Engineers, Skokie, IL, USA)” |
| Camera | “Mice movements were recorded using a camera” | |
| EthoVision XT | Noldus, Wageningen, The Netherlands | “movement tracking and automatic scoring were performed using EthoVision XT 11.5 (Noldus, Wageningen, The Netherlands) software” |
Cited to other work: How immobility time was recorded; no tool or observer is printed. [38].
| Setting | Value | Paper’s words |
|---|---|---|
| Water temperature |
| “filled with water up to 25 cm height (25 ± 2 °C)” |
| Water depth |
| “filled with water up to 25 cm height” |
| Cylinder size |
| “a glass cylinder (30 height × 10 cm diameter)” |
| Session duration |
| “for 6 min and the immobility time was recorded” |
| Other settings in the paper | ||
| Cylinder | glass | “a glass cylinder” |
| Placed | individually | “the mice were placed individually into a glass cylinder” |
| Non-swim time | the time the mice spent immobile | “A non-swim time was measured as the time the mice spent immobile” |
| Warmed under a lamp | Immediately after the test 10 min | “Immediately after the test, the mice were then dried with paper towels, warmed under a lamp for 10 min” |
| Failed to stay afloat | removed immediately | “The animals which failed to stay afloat were removed immediately” |
| Forced swim test | day 5 | “day 5—open field second run and forced swim test” |
| FST paradigm was performed | after the second OFT | “the FST paradigm was performed after the second OFT” |
| Apparatus | ||
| Glass cylinder | “a glass cylinder (30 height × 10 cm diameter)” | |
| Lamp | “warmed under a lamp for 10 min” | |
| Paper towels | “dried with paper towels” | |
| Methods cited to other work | ||
| How immobility time was recorded; no tool or observer is printed | [38] | “the immobility time was recorded [38]” |
Quotes are shown under the paper’s CC BY license. Sentences are split into steps, and the words are unchanged.