© 2026 ConductScience. All rights reserved.

Papers/Sengupta et al. 2016

Replicate Sengupta et al. 2016

Red-shifted channelrhodopsin stimulation restores light responses in blind mice, macaque retina, and human retina

Sengupta A, Chaffiol A, Macé E, et al. EMBO molecular medicine 2016;8(11):1248-1264.

Read the paper (doi:10.15252/emmm.201505699)Full text on PubMed Central (PMC5090658)Download the record as an RO-Crate
  • Animals

    Mice

  • Behavioral tests

    1

  • Settings we look for

    0 of 3 missing

How to run it

Each step is a sentence from the paper’s Methods, word for word. This page covers the behavioral tests this site tracks, so the paper may have run others.

The test records were read three times by AI and checked by code. No person has reviewed them yet. Code placed each sentence under its test from those records. How records are made

The test

  • Open field testStore page for the Open Field Test (opens the store in a new tab)

The store is ConductScience, which runs this site. What it sells may differ from what the paper used.

The animals

  • Male rd1 (n = 9), male WT C57BL6J (n = 9), and male ReaChR‐treated (n = 7) mice were subjected to 5‐min trials during which the compartment was illuminated at different light intensities of orange (590 nm) light.

Open field test

Compare with 10 other papers

What you need

  • Circular open‐field arena
  • 590‐nm LED light sourcesLumitronix, Graefelfing, Germany, Cree XP‐E
  • Handheld spectrophotometerThorlabs, Germany, PM100D
  • Video cameraSony Corporation, Tokyo, Japan, Handycam
  • Ethovision XTNoldus Information Technology, Leesburg, VA
ConductScience sellsOpen Field Test (opens the store in a new tab)
  1. A circular open‐field arena was constructed in house with diameter 36 cm using an aluminum sheet folded in a circle placed over a plexiglass base (similar to the one described in Polosukhina et al, 2012).
  2. Ten 590‐nm LED light sources (Cree XP‐E, Lumitronix, Graefelfing, Germany) were glued to the wall of the open‐field arena.
  3. The irradiance of the open field upon LED illumination was ~1015 photons cm−2 s−1 as measured approximately at the level of the mice's eyes using a handheld spectrophotometer (PM100D, Thorlabs, Germany).
  4. Activity in the arena was recorded during the test by a video camera (Handycam, Sony Corporation, Tokyo, Japan) in night vision mode.
  5. ReaChR‐treated rd1 mice or age‐matched blind rd1 control mice were dark adapted for 30 min before being placed in the center of the open‐field arena.
  6. Their activity was recorded for 2 min followed by 2 min of illumination of the chamber (based on the protocol used in Lagali et al, 2008).
  7. The movies were analyzed using mouse behavior phenotyping and motion tracking software Ethovision XT build 8.0 (Noldus Information Technology, Leesburg, VA).
  8. The mouse was detected using a center of mass algorithm by adjusting the threshold to maximize the contrast between the mouse and background, in the dark and during illumination.
  9. The average velocity and trajectory of the mouse was tracked for 2 min in the dark and for 2 min after light was switched on.
  10. All behavior experiments were run during the dark phase of the mice between 18 and 21 h.

Cited to other work: construction of the circular open-field arena (described as similar to a published arena). Polosukhina et al, 2012.

Cited to other work: dark-then-illumination recording protocol (stated as based on a published protocol). Lagali et al, 2008.

Every setting as a table
SettingValuePaper’s words
Arena size
  • diameter 36 cm

“A circular open‐field arena was constructed in house with diameter 36 cm”
Session duration
  • In the dark

    2 min

  • After light was switched on

    2 min

“Their activity was recorded for 2 min followed by 2 min of illumination of the chamber”
“tracked for 2 min in the dark and for 2 min after light was switched on”
Illumination
  • Upon LED illumination

    ~10^15 photons cm^−2 s^−1

“The irradiance of the open field upon LED illumination was ~10^15 photons cm^−2 s^−1”
Other settings in the paper
Dark adapted

30 min

“blind rd1 control mice were dark adapted for 30 min before being placed in the center”
Placed

in the center

“blind rd1 control mice were dark adapted for 30 min before being placed in the center”
LED light sources

590‐nm

“Ten 590‐nm LED light sources”
590‐nm LED light sources

Ten

“Ten 590‐nm LED light sources”
Video camera

night vision mode

“Activity in the arena was recorded during the test by a video camera (Handycam, Sony Corporation, Tokyo, Japan) in night vision mode”
Run during the dark phase of the mice

between 18 and 21 h

“All behavior experiments were run during the dark phase of the mice between 18 and 21 h”
Apparatus
Circular open‐field arena
“A circular open‐field arena was constructed in house with diameter 36 cm using an aluminum sheet folded in a circle placed over a plexiglass base (similar to the one described in Polosukhina et al, 2012).”
590‐nm LED light sources

Lumitronix, Graefelfing, Germany, Cree XP‐E

“Ten 590‐nm LED light sources (Cree XP‐E, Lumitronix, Graefelfing, Germany) were glued to the wall of the open‐field arena.”
Handheld spectrophotometer

Thorlabs, Germany, PM100D

“as measured approximately at the level of the mice's eyes using a handheld spectrophotometer (PM100D, Thorlabs, Germany)”
Video camera

Sony Corporation, Tokyo, Japan, Handycam

“Activity in the arena was recorded during the test by a video camera (Handycam, Sony Corporation, Tokyo, Japan) in night vision mode.”
Ethovision XT

Noldus Information Technology, Leesburg, VA

“The movies were analyzed using mouse behavior phenotyping and motion tracking software Ethovision XT build 8.0 (Noldus Information Technology, Leesburg, VA).”
Methods cited to other work
Construction of the circular open-field arena (described as similar to a published arena)

Polosukhina et al, 2012

“similar to the one described in Polosukhina et al, 2012”
Dark-then-illumination recording protocol (stated as based on a published protocol)

Lagali et al, 2008

“based on the protocol used in Lagali et al, 2008”

Quotes are shown under the paper’s CC BY license. Sentences are split into steps, and the words are unchanged.