ReplicateScience
TestsPapersMethodologyAboutOffline
Submit a paper
ReplicateScience

Records of how behavioral tests were run, taken from open-access papers. Built by ConductScience.

Browse

  • Tests
  • Papers
  • Scientists
  • Institutions

About

  • Methodology
  • About
  • Submit a paper
  • Offline edition
  • ConductScience

Legal

  • Privacy
  • Terms

© 2026 ConductScience. All rights reserved.

Papers/Fang et al. 2018

Replicate Fang et al. 2018

Early Changes of Articular Cartilage and Subchondral Bone in The DMM Mouse Model of Osteoarthritis

Fang H, Huang L, Welch I, et al. Scientific reports 2018;8(1):2855.

Read the paper (doi:10.1038/s41598-018-21184-5)Full text on PubMed Central (PMC5809364)Download the record as an RO-Crate
  • Animals

    Mice

  • Behavioral tests

    1

  • Settings we look for

    0 of 4 missing

How to run it

Each step is a sentence from the paper’s Methods, word for word. This page covers the behavioral tests this site tracks, so the paper may have run others.

The test records were read three times by AI and checked by code. No person has reviewed them yet. Code placed each sentence under its test from those records. How records are made

The test

  • Gait analysisStore page for the Gait Test (opens the store in a new tab)

The store is ConductScience, which runs this site. What it sells may differ from what the paper used.

The animals

  • C57/Bl6 wild type mice were randomly designated into 2 groups: DMM and SHAM, and three termination time-points (2, 5 and 10 weeks post-surgery).

Gait analysis

Compare with 8 other papers

What you need

  • Catwalk^® gait analysis systemNoldus Inc.
  • Catwalk^® software
ConductScience sellsGait Test (opens the store in a new tab)
  1. Mice were weighed and transferred to the Behavior Study Suite at Robarts Research Institute at Western University two days prior to gait acquisitions.
  2. Gait patterns and relative parameters were captured by the Catwalk® gait analysis system (Noldus Inc.) as described22.
  3. Briefly, mice were placed on a glass platform located in a dark room and allowed to move freely.
  4. A light beam from a fluorescent lamp illuminates the platform.
  5. Where the paw touches the glass surface, an image of the paw print is recorded by a camera underneath.
  6. Gait was captured and parameters was obtained from the Catwalk® software for statistical analysis.

Cited to other work: Catwalk gait acquisition procedure (walkway, run criteria, number of runs, camera settings). as described^22 (reference 22).

Every setting as a table
SettingValuePaper’s words
Walkway size, run duration criterion, number of runs, camera frame rate
  • Cited to other work
“captured by the Catwalk^® gait analysis system (Noldus Inc.) as described^22”
Other settings in the paper
Transferred to the Behavior Study Suite ... prior to gait acquisitions

two days

“transferred to the Behavior Study Suite at Robarts Research Institute at Western University two days prior to gait acquisitions”
Room

dark

“mice were placed on a glass platform located in a dark room”
Apparatus
Catwalk^® gait analysis system

Noldus Inc.

“Gait patterns and relative parameters were captured by the Catwalk^® gait analysis system (Noldus Inc.) as described^22.”
Catwalk^® software
“Gait was captured and parameters was obtained from the Catwalk^® software for statistical analysis.”
Methods cited to other work
Catwalk gait acquisition procedure (walkway, run criteria, number of runs, camera settings)

as described^22 (reference 22)