Walkway size

Dimensions of the gait walkway or runway

PaperValuePaper’s words
Drapeau et al. 2018Mice
  • 152 cm long × 10 cm wide

“an elevated runway (dimensions: 152 cm long × 10 cm wide)”
Florez-Paz et al. 2016Mice
  • 85 cm long and 8.5 cm wide

“the mice were placed in a glass chamber (85 cm long and 8.5 cm wide) and they were allowed to move freely across the walkway”
Ahire et al. 2023Mice
  • Cited to other work

    No walkway dimensions are given; the CatWalk procedure is described only by citing a previously reported protocol.

“using our previously reported protocol (Ungvari et al., 2017)”
Fang et al. 2018Mice
  • Cited to other work

    The glass platform is named but no dimensions are given. The Catwalk acquisition method is referred to ref. 22.

“captured by the Catwalk^® gait analysis system (Noldus Inc.) as described^22”

Not in the Methods of Tsuji et al. 2026, Johnston et al. 2025, Wen et al. 2024, Xin et al. 2017, Huang et al. 2016.

Run duration criterion

The time limits a run must fall within to count

PaperValuePaper’s words
Xin et al. 2017Mice
  • ⩽10 s

“A successful trial was defined as the mouse taking ⩽10 s to cross the field of vision of a video camera”
Wen et al. 2024Mice
  • Unclear

    within 5 s

    The 5 s is a time window for 10 consecutive strides in a treadmill video. It limits which videos were analyzed, but the passage does not call it a limit on run duration.

“Videos with at least 10 consecutive strides within 5 s were analyzed using the DigiGait software”
Ahire et al. 2023Mice
  • Cited to other work

    No run duration criterion is given; the CatWalk procedure is described only by citing a previously reported protocol.

“using our previously reported protocol (Ungvari et al., 2017)”
Fang et al. 2018Mice
  • Cited to other work

    No run duration limits are given. The acquisition method is referred to ref. 22.

“captured by the Catwalk^® gait analysis system (Noldus Inc.) as described^22”

Not in the Methods of Tsuji et al. 2026, Johnston et al. 2025, Drapeau et al. 2018, Florez-Paz et al. 2016, Huang et al. 2016.

Number of runs

How many runs are recorded or required for each animal

PaperValuePaper’s words
Drapeau et al. 2018Mice
  • two consecutive runs

“to record paw prints on two consecutive runs”
Xin et al. 2017Mice
  • Each training day

    three trials

  • The test day

    two trials

“Each mouse successfully completed three trials on each training day”
“Each mouse successfully completed three trials on each training day and two trials on the test day.”
Florez-Paz et al. 2016Mice
  • at least three times

“scored all the tests, each of which was repeated at least three times in each animal”
“the values from the individual tracks were averaged”
Ahire et al. 2023Mice
  • Cited to other work

    No number of runs is given; the CatWalk procedure is described only by citing a previously reported protocol.

“using our previously reported protocol (Ungvari et al., 2017)”
Fang et al. 2018Mice
  • Cited to other work

    The number of runs per mouse is not given. The acquisition method is referred to ref. 22.

“captured by the Catwalk^® gait analysis system (Noldus Inc.) as described^22”

Not in the Methods of Tsuji et al. 2026, Johnston et al. 2025, Wen et al. 2024, Huang et al. 2016.

Camera frame rate

Frames per second of the camera that records the runs

PaperValuePaper’s words
Ahire et al. 2023Mice
  • Cited to other work

    No frame rate is given; the whole CatWalk protocol is referred to prior work.

“using our previously reported protocol (Ungvari et al., 2017)”
Fang et al. 2018Mice
  • Cited to other work

    A camera underneath the platform is mentioned, but no frame rate is given. The acquisition method is referred to ref. 22.

“captured by the Catwalk^® gait analysis system (Noldus Inc.) as described^22”

Not in the Methods of Tsuji et al. 2026, Johnston et al. 2025, Wen et al. 2024, Drapeau et al. 2018, Xin et al. 2017, Florez-Paz et al. 2016, Huang et al. 2016.

Other settings the papers report (33)

Settings outside the list above, named as each paper names them.

PaperSetting and valuePaper’s words
Wen et al. 2024Mice

Acclimated in the treadmill compartment

1 min

“Animal was acclimated in the treadmill compartment for 1 min”
Xin et al. 2017Mice

Allowed to acclimate

10 min

“the mouse was placed in an enclosed box at the end of the walkway and allowed to acclimate for 10 min”
Drapeau et al. 2018Mice

Analysis of

50 cm

“for analysis of 50 cm”
Drapeau et al. 2018Mice

Behavioral experiments were conducted

between 9 A.M. and 5 P.M.

“Behavioral experiments were conducted between 9 A.M. and 5 P.M.”
Xin et al. 2017Mice

Ceiling light

red

“with a green light on the walkway and a red ceiling light to illuminate the mouse”
Wen et al. 2024Mice

Consecutive strides

at least 10

“Videos with at least 10 consecutive strides within 5 s were analyzed using the DigiGait software”
Wen et al. 2024Mice

Divided into

two batches

“animals were randomly divided into two batches and tested separately for balance beam, DigiGait, and Barnes maze tests”
Wen et al. 2024Mice

Gradually increased to the testing speed

over several seconds

“gradually increased to the testing speed over several seconds”
Wen et al. 2024Mice

High-speed video camera

positioned below the transparent belt

“a high-speed video camera positioned below the transparent belt”
Xin et al. 2017Mice

Light on the walkway

green

“with a green light on the walkway and a red ceiling light to illuminate the mouse”
Xin et al. 2017Mice

Lights

turned off

“after which the lights were turned off”
Drapeau et al. 2018Mice

Lined with

white paper

“lined with white paper”
Wen et al. 2024Mice

Low speed

5 cm/s

“treadmill was turned on at a low speed (5 cm/s)”
Johnston et al. 2025Mice

Measurements were taken

from the center of the right hind paw to the same hind paw center a stride later

“Measurements were taken from the center of the right hind paw to the same hind paw center a stride later”
Drapeau et al. 2018Mice

Mice were brought to the front room of the testing area

at least half an hour

“Mice were brought to the front room of the testing area at least half an hour before the start of experiments”
Drapeau et al. 2018Mice

Nontoxic paint

different colors for hind and front paws

“coated in nontoxic paint (different colors for hind and front paws)”
Wen et al. 2024Mice

Order of tests, batch 1

Day 33

“Day 33, DigiGait for batch 1”
Wen et al. 2024Mice

Order of tests, batch 2

Day 40

“Day 40, DigiGait for batch 2”
Johnston et al. 2025Mice

Paws dipped in

water-soluble paint

“had paws dipped in water-soluble paint”
Johnston et al. 2025Mice

Placed on

a large sheet of white paper

“were placed on a large sheet of white paper”
Tsuji et al. 2026Mice

Preflight metrics, first down-selection

suboptimal or poor

“The first down-selection process excluded mice that exhibited health concerns, suboptimal or poor preflight metrics [<1 fecal pellet, dual-energy x-ray absorptiometry (DXA), gait analysis using DigiGait (Mouse Specifics Inc., Seaford, DE, USA)]”
Wen et al. 2024Mice

Rest in between tests

at least a 1-day

“Animals were given at least a 1-day rest in between tests”
Fang et al. 2018Mice

Room

dark

“mice were placed on a glass platform located in a dark room”
Wen et al. 2024Mice

Speeds

10 cm/s, 20 cm/s, and 30 cm/s

“Each mouse was tested on three speeds: 10 cm/s, 20 cm/s, and 30 cm/s”
Xin et al. 2017Mice

Tested

the fourth day

“The mice were trained for three consecutive days and were tested on the fourth day.”
Xin et al. 2017Mice

Tests were repeated

once a week

“Thereafter, the tests were repeated once a week until the mice could no longer complete the tests.”
Drapeau et al. 2018Mice

The record displaying

the clearest prints and most consistent gait

“The record displaying the clearest prints and most consistent gait”
Huang et al. 2016Rats

The test was performed

1, 2, 3, and 6 weeks after injury

“The test was performed 1, 2, 3, and 6 weeks after injury.”
Xin et al. 2017Mice

Trained

three consecutive days

“The mice were trained for three consecutive days and were tested on the fourth day.”
Drapeau et al. 2018Mice

Training runs

three

“After three training runs”
Fang et al. 2018Mice

Transferred to the Behavior Study Suite ... prior to gait acquisitions

two days

“transferred to the Behavior Study Suite at Robarts Research Institute at Western University two days prior to gait acquisitions”
Wen et al. 2024Mice

Unable to walk at the target speed

removed from the study

“Animals that were unable to walk at the target speed were removed from the study”
Huang et al. 2016Rats

Wide-angle lens

8.5-mm

“equipped with an 8.5-mm wide-angle lens”

Apparatus

What each paper names for this test. Vendors and models appear as the paper prints them.

PaperApparatusPaper’s words
Tsuji et al. 2026

DigiGait

Mouse Specifics Inc.

“gait analysis using DigiGait (Mouse Specifics Inc., Seaford, DE, USA)”
Johnston et al. 2025

Water-soluble paint

“had paws dipped in water-soluble paint”
Johnston et al. 2025

Large sheet of white paper

“were placed on a large sheet of white paper to measure gait/stride length”
Wen et al. 2024

DigiGait Imaging System

Mouse Specifics

“the DigiGait Imaging System (Mouse Specifics, Framingham, MA)”
Wen et al. 2024

DigiGait treadmill

“Videos of the mice walked on the DigiGait treadmill”
Wen et al. 2024

High-speed video camera

“a high-speed video camera positioned below the transparent belt”
Wen et al. 2024

DigiGait software

“were analyzed using the DigiGait software”
Ahire et al. 2023

CatWalk

Noldus Information Technology Inc.

“we tested the experimental groups of mice using an automated computer assisted method (CatWalk; Noldus Information Technology Inc.)”
Drapeau et al. 2018

Elevated runway

“an elevated runway (dimensions: 152 cm long × 10 cm wide)”
Drapeau et al. 2018

White paper

“lined with white paper”
Drapeau et al. 2018

Nontoxic paint

“paws were coated in nontoxic paint”
Fang et al. 2018

Catwalk^® gait analysis system

Noldus Inc.

“Gait patterns and relative parameters were captured by the Catwalk^® gait analysis system (Noldus Inc.) as described^22.”
Fang et al. 2018

Catwalk^® software

“Gait was captured and parameters was obtained from the Catwalk^® software for statistical analysis.”
Xin et al. 2017

CatWalk XT system

Noldus Information Technology

“we used the CatWalk XT system [37–39] (Noldus Information Technology, Wageningen, The Netherlands)”
Xin et al. 2017

CatWalk XT software

“which was analyzed by CatWalk XT software”
Florez-Paz et al. 2016

CatWalk system 7.1

Noldus Information Technology

“The animal’s gait was tested with the CatWalk system 7.1 (Noldus Information Technology), where the mice were placed in a glass chamber (85 cm long and 8.5 cm wide) and they were allowed to move freely across the walkway.”
Florez-Paz et al. 2016

CatWalk software

“allowing the paw prints to be captured by a video camera and analyzed with the CatWalk software”
Huang et al. 2016

CatWalk system

Noldus Inc.

“Motor function was determined by stand time and footprint intensity using the CatWalk system (Noldus Inc., Wageningen, Netherlands)”
Huang et al. 2016

High-speed video camera

Gevicam, GP-3360

“a GP-3360 high-speed video camera (Gevicam, Milpitas, CA, USA)”
Huang et al. 2016

Wide-angle lens

Fujicon Corp.