Papers/Johnston et al. 2025

Replicate Johnston et al. 2025

Growth hormone-deficient Ames dwarf mice resist sarcopenia and exhibit enhanced endurance running performance at 24 months

Johnston MJ, Rakoczy SG, Thompson LV, et al. GeroScience 2025;47(3):4827-4843.

Read the paper (doi:10.1007/s11357-025-01630-9)Full text on PubMed Central (PMC12181600)Download the record as an RO-Crate
  • Animals

    Mice

  • Behavioral tests

    3

  • Test orderPartly stated
  • Settings we look for

    3 of 7 missing

How to run it

Each step is a sentence from the paper’s Methods, word for word. This page covers the behavioral tests this site tracks, so the paper may have run others.

The test records were read once by AI and checked by code. No person has reviewed them yet. Code placed each sentence under its test from those records. How records are made

The tests

  • Grip strength testStore page for the Grip Strength Test (opens the store in a new tab)
  • Rotarod testStore page for the Rotarod (opens the store in a new tab)
  • Gait analysisStore page for the Gait Test (opens the store in a new tab)

The store is ConductScience, which runs this site. What it sells may differ from what the paper used. Maze Engineers is a ConductScience brand.

Order of the tests

  • Grip strength and rotarod tests were performed on the same day, with endurance running testing taking place the following day to avoid fatigue/stress.

Shared between tests

  • Mice were housed together in groups of 2–4, with wildtype controls being housed individually in instances where fighting or minor injuries were observed.The animals
  • Fitness tests were derived from the comprehensive functional assessment battery (CFAB), a set of noninvasive tests used to assess and compare the physical function and motor task ability of rodents [18].Grip strength test and rotarod test
  • All participants underwent fitness testing once per month over a period of 6 months.Grip strength test and rotarod test

Grip strength test

Compare with 6 other papers

What you need

  • Maze Engineers Grip Strength Instrument
ConductScience sellsGrip Strength Test (opens the store in a new tab)
  1. The conventional forelimb grip strength test is a method to assess skeletal muscle function in rodents; in this study, we modified this method to include all four limbs to reduce variability and improve consistency.
  2. Grip strength was recorded via Maze Engineers Grip Strength Instrument (Skokie, IL, USA).
  3. The apparatus has a maximum tensile force range from 0 to 50 N, a reading accuracy of 0.1 g steps, and an error of ≤ 0.3 g.
  4. To measure grip strength, mice were gently lifted by the tail so that both the fore and hind paws could grasp the steel grid.
  5. Mice were then gently pulled away from the apparatus by the tail until the grip was released.
  6. Peak force was the objective of the assessment.
  7. On testing days, animals were first weighed and then given a set of 5 grip strength trials.
  8. For data normalization, the top and bottom scores from each animal were eliminated, with the remaining 3 trials being averaged and then divided by the animal’s bodyweight, in grams, to produce a final evaluation of relative fitness expressed in peak force/grams bodyweight.

Cited to other work: the battery the fitness tests were derived from, the comprehensive functional assessment battery (CFAB). [18].

Every setting as a table
SettingValuePaper’s words
Number of trials
  • 5 grip strength trials

“animals were first weighed and then given a set of 5 grip strength trials”
Other settings in the paper
Limbs

all four limbs

“we modified this method to include all four limbs”
Maximum tensile force range

0 to 50 N

“a maximum tensile force range from 0 to 50 N”
Reading accuracy

0.1 g steps

“a reading accuracy of 0.1 g steps”
Error

≤ 0.3 g

“an error of ≤ 0.3 g”
Grid

steel grid

“both the fore and hind paws could grasp the steel grid”
Gently pulled away from the apparatus by the tail

until the grip was released

“gently pulled away from the apparatus by the tail until the grip was released”
Objective of the assessment

Peak force

“Peak force was the objective of the assessment”
Fitness testing

once per month

“All participants underwent fitness testing once per month over a period of 6 months”
Period

6 months

“All participants underwent fitness testing once per month over a period of 6 months”
Grip strength and rotarod tests were performed

on the same day

“Grip strength and rotarod tests were performed on the same day”
Apparatus
Maze Engineers Grip Strength Instrument
“Grip strength was recorded via Maze Engineers Grip Strength Instrument (Skokie, IL, USA)”
Methods cited to other work
The battery the fitness tests were derived from, the comprehensive functional assessment battery (CFAB)

[18]

“Fitness tests were derived from the comprehensive functional assessment battery (CFAB), a set of noninvasive tests used to assess and compare the physical function and motor task ability of rodents [18]”

Rotarod test

Compare with 9 other papers

What you need

  • Maze Engineers Rotarod Instrument
ConductScience sellsRotarod (opens the store in a new tab)
  1. Rotarod testing was recorded utilizing Maze Engineers Rotarod Instrument (Skokie, IL, USA).
  2. The apparatus features dividers to prevent mice from entering other lanes and was further fitted with 50% smaller rotating dowels in half the lanes to accommodate the diminutive stature of dwarf mice.
  3. The rotarod dowels rotate at an increasing speed with mice attempting to remain on it rather than fall onto a platform just below.
  4. Testing consisted of 5 min maximum latency with rotation starting at 4 revolutions/min and increasing steadily at 7.2 revolutions/min2 until a maximum speed of 40 revolutions/min was reached.
  5. When mice fell from the rotating dowel, their latency was automatically recorded via the motion sensor on the apparatus.
  6. On testing days, mice performed 3 trials of rotarod with a break of>10 min between trials.
  7. Final scores were obtained by averaging the latency of three trials expressed in seconds.

Cited to other work: the battery the fitness tests were derived from, the comprehensive functional assessment battery (CFAB), and the use of rotarod as a performance and behavioral task. [18].

Every setting as a table
SettingValuePaper’s words
Rod speed
  • Starting

    4 revolutions/min

  • Maximum speed

    40 revolutions/min

“rotation starting at 4 revolutions/min”
“until a maximum speed of 40 revolutions/min”
Trial duration
  • 5 min

“Testing consisted of 5 min maximum latency”
Number of trials
  • 3 trials

“On testing days, mice performed 3 trials of rotarod”
Other settings in the paper
Increasing steadily

7.2 revolutions/min^2

“increasing steadily at 7.2 revolutions/min^2”
Break

Between trials

>10 min

“a break of>10 min between trials”
Rotating dowels

In half the lanes

50% smaller

“50% smaller rotating dowels in half the lanes”
Latency

automatically recorded via the motion sensor on the apparatus

“their latency was automatically recorded via the motion sensor on the apparatus”
Fitness testing

once per month

“All participants underwent fitness testing once per month over a period of 6 months”
Period

6 months

“All participants underwent fitness testing once per month over a period of 6 months”
Grip strength and rotarod tests were performed

on the same day

“Grip strength and rotarod tests were performed on the same day”
Apparatus
Maze Engineers Rotarod Instrument
“Rotarod testing was recorded utilizing Maze Engineers Rotarod Instrument (Skokie, IL, USA)”
Methods cited to other work
The battery the fitness tests were derived from, the comprehensive functional assessment battery (CFAB), and the use of rotarod as a performance and behavioral task

[18]

“Fitness tests were derived from the comprehensive functional assessment battery (CFAB), a set of noninvasive tests used to assess and compare the physical function and motor task ability of rodents [18]”

Gait analysis

Compare with 8 other papers

What you need

  • Water-soluble paint
  • Large sheet of white paper
ConductScience sellsGait Test (opens the store in a new tab)
  1. Male Ames dwarf and wildtype controls from middle-aged (8–12 months) and aged (18+ m.o.) had paws dipped in water-soluble paint and were placed on a large sheet of white paper to measure gait/stride length.
  2. Measurements were taken from the center of the right hind paw to the same hind paw center a stride later.

Not in the Methods: Walkway size, run duration criterion and number of runs.

Every setting as a table
SettingValuePaper’s words
Not in the MethodsWalkway size, run duration criterion, number of runs
Other settings in the paper
Paws dipped in

water-soluble paint

“had paws dipped in water-soluble paint”
Placed on

a large sheet of white paper

“were placed on a large sheet of white paper”
Measurements were taken

from the center of the right hind paw to the same hind paw center a stride later

“Measurements were taken from the center of the right hind paw to the same hind paw center a stride later”
Apparatus
Water-soluble paint
“had paws dipped in water-soluble paint”
Large sheet of white paper
“were placed on a large sheet of white paper to measure gait/stride length”