Johnston MJ, Rakoczy SG, Thompson LV, et al. GeroScience 2025;47(3):4827-4843.
The test records were read once by AI and checked by code. No person has reviewed them yet. How records are made
| Setting | Value | Paper’s words |
|---|---|---|
| Not in the Methods | Walkway size, run duration criterion, number of runs | |
| Other settings in the paper | ||
| Paws dipped in | water-soluble paint | “had paws dipped in water-soluble paint” |
| Placed on | a large sheet of white paper | “were placed on a large sheet of white paper” |
| Measurements were taken | from the center of the right hind paw to the same hind paw center a stride later | “Measurements were taken from the center of the right hind paw to the same hind paw center a stride later” |
| Apparatus | ||
| Water-soluble paint | “had paws dipped in water-soluble paint” | |
| Large sheet of white paper | “were placed on a large sheet of white paper to measure gait/stride length” | |
| Setting | Value | Paper’s words |
|---|---|---|
| Number of trials |
| “animals were first weighed and then given a set of 5 grip strength trials” |
| Other settings in the paper | ||
| Limbs | all four limbs | “we modified this method to include all four limbs” |
| Maximum tensile force range | 0 to 50 N | “a maximum tensile force range from 0 to 50 N” |
| Reading accuracy | 0.1 g steps | “a reading accuracy of 0.1 g steps” |
| Error | ≤ 0.3 g | “an error of ≤ 0.3 g” |
| Grid | steel grid | “both the fore and hind paws could grasp the steel grid” |
| Gently pulled away from the apparatus by the tail | until the grip was released | “gently pulled away from the apparatus by the tail until the grip was released” |
| Objective of the assessment | Peak force | “Peak force was the objective of the assessment” |
| Fitness testing | once per month | “All participants underwent fitness testing once per month over a period of 6 months” |
| Period | 6 months | “All participants underwent fitness testing once per month over a period of 6 months” |
| Grip strength and rotarod tests were performed | on the same day | “Grip strength and rotarod tests were performed on the same day” |
| Apparatus | ||
| Maze Engineers Grip Strength Instrument | “Grip strength was recorded via Maze Engineers Grip Strength Instrument (Skokie, IL, USA)” | |
| Methods cited to other work | ||
| The battery the fitness tests were derived from, the comprehensive functional assessment battery (CFAB) | [18] | “Fitness tests were derived from the comprehensive functional assessment battery (CFAB), a set of noninvasive tests used to assess and compare the physical function and motor task ability of rodents [18]” |
| Setting | Value | Paper’s words |
|---|---|---|
| Rod speed |
| “rotation starting at 4 revolutions/min” “until a maximum speed of 40 revolutions/min” |
| Trial duration |
| “Testing consisted of 5 min maximum latency” |
| Number of trials |
| “On testing days, mice performed 3 trials of rotarod” |
| Other settings in the paper | ||
| Increasing steadily | 7.2 revolutions/min^2 | “increasing steadily at 7.2 revolutions/min^2” |
| Break | Between trials >10 min | “a break of>10 min between trials” |
| Rotating dowels | In half the lanes 50% smaller | “50% smaller rotating dowels in half the lanes” |
| Latency | automatically recorded via the motion sensor on the apparatus | “their latency was automatically recorded via the motion sensor on the apparatus” |
| Fitness testing | once per month | “All participants underwent fitness testing once per month over a period of 6 months” |
| Period | 6 months | “All participants underwent fitness testing once per month over a period of 6 months” |
| Grip strength and rotarod tests were performed | on the same day | “Grip strength and rotarod tests were performed on the same day” |
| Apparatus | ||
| Maze Engineers Rotarod Instrument | “Rotarod testing was recorded utilizing Maze Engineers Rotarod Instrument (Skokie, IL, USA)” | |
| Methods cited to other work | ||
| The battery the fitness tests were derived from, the comprehensive functional assessment battery (CFAB), and the use of rotarod as a performance and behavioral task | [18] | “Fitness tests were derived from the comprehensive functional assessment battery (CFAB), a set of noninvasive tests used to assess and compare the physical function and motor task ability of rodents [18]” |