Rotation speed of the rotarod rod: one fixed speed, or the start and end speeds of an accelerating run
| Paper | Value | Paper’s words |
|---|---|---|
| Johnston et al. 2025Mice |
| “rotation starting at 4 revolutions/min” “until a maximum speed of 40 revolutions/min” |
| Wen et al. 2024Mice |
| “For the training trial, mice were placed on the rotarod with a constant speed of four revolutions per minute (rpm) for 5 min” “For the testing trial, the rotarod was set to accelerate from 4 to 40 rpm over the course of 5 min” |
| Trabjerg et al. 2023Mice |
| “The speed was increased from 5 to 40 RPM within 140 s for the C57Bl/6J rotenone etomoxir experiment” “The speed was optimized for the other experiments” “Starting at 5 RPM and ending at 40 RPM at 140 s” |
| Somebang et al. 2021Mice |
| “a rotating rod that accelerated to 40 rpm over 300 s” |
| Trabjerg et al. 2021Mice |
| “an acceleration from 4 to 40 RPM over 5 min” |
| Drapeau et al. 2018Mice |
| “a linear acceleration from 4 to 40 rpm” |
| Xin et al. 2017Mice |
| “three 5-min training trials with the speed set to 10, 12 and 14 r.p.m.” “During testing, the rotarod speed was increased from 4 to 40 r.p.m. over a 5-min period” |
| Florez-Paz et al. 2016Mice |
| “The initial speed of rotation was 5 rpm and it accelerated to 20 rpm” |
Not in the Methods of Ahire et al. 2023, Rattner et al. 2020.
The fixed or longest length of one trial
| Paper | Value | Paper’s words |
|---|---|---|
| Johnston et al. 2025Mice |
| “Testing consisted of 5 min maximum latency” |
| Trabjerg et al. 2023Mice |
| “The cut-off time was set to 180 s” |
| Drapeau et al. 2018Mice |
| “Each trial lasted for a maximum of 5 min” |
| Wen et al. 2024Mice |
| “For the training trial, mice were placed on the rotarod with a constant speed of four revolutions per minute (rpm) for 5 min” “For the testing trial, the rotarod was set to accelerate from 4 to 40 rpm over the course of 5 min” |
| Xin et al. 2017Mice |
| “three 5-min training trials” “the rotarod speed was increased from 4 to 40 r.p.m. over a 5-min period” |
| Trabjerg et al. 2021Mice |
| “an acceleration from 4 to 40 RPM over 5 min” |
Not in the Methods of Ahire et al. 2023, Somebang et al. 2021, Rattner et al. 2020, Florez-Paz et al. 2016.
How many trials an animal gets in one session or day
| Paper | Value | Paper’s words |
|---|---|---|
| Johnston et al. 2025Mice |
| “On testing days, mice performed 3 trials of rotarod” |
| Wen et al. 2024Mice |
| “Each mouse was tested for three testing trials with 10–15 min to rest in between trials” |
| Trabjerg et al. 2023Mice |
| “Each animal received three trials per session” “Prior to the rotarod performance test, mice were trained on three different dates with three trials per session” |
| Somebang et al. 2021Mice |
| “Animals were assessed five trials/day for two days.” |
| Trabjerg et al. 2021Mice |
| “Each mouse was tested three times per test session” |
| Drapeau et al. 2018Mice |
| “for three trials per day on two consecutive days” |
| Xin et al. 2017Mice |
| “with three 5-min training trials with the speed set to 10, 12 and 14 r.p.m.” “trained on the rotarod for three consecutive days” |
| Florez-Paz et al. 2016Mice |
| “all the tests, each of which was repeated at least three times in each animal” |
Not in the Methods of Ahire et al. 2023, Rattner et al. 2020.
Settings outside the list above, named as each paper names them.
| Paper | Setting and value | Paper’s words |
|---|---|---|
| Wen et al. 2024Mice | Accelerate from 4 to 40 rpm over the course of, testing trial 5 min | “For the testing trial, the rotarod was set to accelerate from 4 to 40 rpm over the course of 5 min” |
| Somebang et al. 2021Mice | Accelerated to 40 rpm over 300 s | “a rotating rod that accelerated to 40 rpm over 300 s” |
| Drapeau et al. 2018Mice | Accelerating rod 3 cm in diameter | “an elevated accelerating rod (3 cm in diameter)” |
| Trabjerg et al. 2023Mice | Acceleration, the other experiments 2.5 RPM per 10 s | “The speed was optimized for the other experiments, using an acceleration of 2.5 RPM per 10 s” |
| Trabjerg et al. 2021Mice | Acceleration over 5 min | “an acceleration from 4 to 40 RPM over 5 min” |
| Drapeau et al. 2018Mice | Acceleration linear | “a linear acceleration from 4 to 40 rpm” |
| Trabjerg et al. 2021Mice | Acclimatized to the rotarod, before the first test session three consecutive days | “Mice were acclimatized to the rotarod over three consecutive days before the first test session” |
| Somebang et al. 2021Mice | After TBI three weeks | “three weeks after TBI” |
| Trabjerg et al. 2023Mice | All tests were performed between 10:00 and 16:00 in the lights-on cycle | “All tests were performed between 10:00 and 16:00 in the lights-on cycle” |
| Somebang et al. 2021Mice | Animals were assessed two days | “Animals were assessed five trials/day for two days.” |
| Drapeau et al. 2018Mice | Behavioral experiments were conducted between 9 A.M. and 5 P.M. | “Behavioral experiments were conducted between 9 A.M. and 5 P.M.” |
| Johnston et al. 2025Mice | Break, between trials >10 min | “a break of>10 min between trials” |
| Trabjerg et al. 2021Mice | Cleaned with 70% ethanol between each animal | “Test equipment was cleaned with 70% ethanol between each animal” |
| Drapeau et al. 2018Mice | Consecutive days two consecutive days | “for three trials per day on two consecutive days” |
| Trabjerg et al. 2023Mice | Data were excluded if the mice continuously jumped off the rotarod or turned in the wrong direction before acceleration | “Data were excluded if the mice continuously jumped off the rotarod or turned in the wrong direction before acceleration” |
| Florez-Paz et al. 2016Mice | Diameter rotating cylinder 5 cm | “the mice were placed on a 5 cm diameter rotating cylinder” |
| Trabjerg et al. 2023Mice | Ending at 40 RPM, the other experiments at 140 s | “Starting at 5 RPM and ending at 40 RPM at 140 s” |
| Trabjerg et al. 2021Mice | Evaluated weekly | “Mice were evaluated weekly by neurological score, grip strength, hangwire test, rotarod test” |
| Trabjerg et al. 2023Mice | Experimenters blinded to treatment groups | “The experimenters were blinded to treatment groups for all behavioral studies” |
| Rattner et al. 2020Mice | Experimenters blind to the genotype | “During all behavioral testing, the experimenters were blind to the genotype” |
| Trabjerg et al. 2023Mice | Exposed to behavioral tests in a randomized order | “The mice were exposed to behavioral tests in a randomized order” |
| Johnston et al. 2025Mice | Fitness testing once per month | “All participants underwent fitness testing once per month over a period of 6 months” |
| Trabjerg et al. 2023Mice | Full cleaning protocol, Between every test 70% ethanol | “Between every test, a full cleaning protocol by 70% ethanol was applied to the surfaces of the equipment” |
| Johnston et al. 2025Mice | Grip strength and rotarod tests were performed on the same day | “Grip strength and rotarod tests were performed on the same day” |
| Johnston et al. 2025Mice | Increasing steadily 7.2 revolutions/min^2 | “increasing steadily at 7.2 revolutions/min^2” |
| Drapeau et al. 2018Mice | Interval, between trials 20-min | “A 20-min interval was used between trials” |
| Ahire et al. 2023Mice | Lane four‐lane | “automated four‐lane rotarod tool” |
| Johnston et al. 2025Mice | Latency automatically recorded via the motion sensor on the apparatus | “their latency was automatically recorded via the motion sensor on the apparatus” |
| Trabjerg et al. 2023Mice | Mice were acclimatized to the laboratory 30 min before tests began | “mice were acclimatized to the laboratory 30 min before tests began” |
| Drapeau et al. 2018Mice | Mice were brought to the front room of the testing area at least half an hour | “Mice were brought to the front room of the testing area at least half an hour before the start of experiments” |
| Trabjerg et al. 2023Mice | Mice were evaluated, Park2 etomoxir experiment At day 22 | “At day 22, mice were evaluated for pathological motor and non-motor behavior using rotarod, grip strength, Y-maze, novel object recognition, and dark-light box test” |
| Trabjerg et al. 2023Mice | Mice were evaluated, Park2 rotenone washout etomoxir experiment At day 54 | “At day 54, mice were evaluated for pathological motor and non-motor behavior using rotarod, grip strength, Y-maze, and novel object recognition” |
| Trabjerg et al. 2023Mice | Mice were trained on, Prior to the rotarod performance test three different dates | “Prior to the rotarod performance test, mice were trained on three different dates with three trials per session” |
| Trabjerg et al. 2023Mice | Motor test, chronic rotenone mouse models day 60 | “motor test at day 60 (rotarod)” |
| Wen et al. 2024Mice | Order of tests Day 10 | “Day 10, rotarod” |
| Trabjerg et al. 2021Mice | Performed between 9 am and 2 pm | “All clinical behavioral tests were performed between 9 am and 2 pm” |
| Johnston et al. 2025Mice | Period 6 months | “All participants underwent fitness testing once per month over a period of 6 months” |
| Xin et al. 2017Mice | Period over which the rotarod speed was increased, testing 5-min | “the rotarod speed was increased from 4 to 40 r.p.m. over a 5-min period” |
| Trabjerg et al. 2021Mice | Placed in the room one hour before test sessions | “mice were placed in the room one hour before test sessions to allow time for acclimatization” |
| Wen et al. 2024Mice | Rest in between tests at least a 1-day | “Animals were given at least a 1-day rest in between tests” |
| Wen et al. 2024Mice | Rest in between trials, testing trials 10–15 min | “Each mouse was tested for three testing trials with 10–15 min to rest in between trials” |
| Johnston et al. 2025Mice | Rotating dowels, in half the lanes 50% smaller | “50% smaller rotating dowels in half the lanes” |
| Trabjerg et al. 2023Mice | Speed was increased, C57Bl/6J rotenone etomoxir experiment within 140 s | “The speed was increased from 5 to 40 RPM within 140 s for the C57Bl/6J rotenone etomoxir experiment” |
| Xin et al. 2017Mice | The tests were repeated once a week | “Thereafter, the tests were repeated once a week until the mice could no longer complete the tests.” |
| Xin et al. 2017Mice | Trained on the rotarod, training three consecutive days | “trained on the rotarod for three consecutive days” |
| Trabjerg et al. 2023Mice | Were defined by the presence of, At day 32 a minimum two of the following factors | “At day 32, animals, who did not show signs of disease, were defined by the presence of a minimum two of the following factors: lower grip strength, lower latency to fall on the rotarod, longer time to transverse the beam, pole or lower number of rears in the cylinder test” |
| Xin et al. 2017Mice | Were tested on the fourth day | “The mice were trained for three consecutive days and were tested on the fourth day.” |
What each paper names for this test. Vendors and models appear as the paper prints them.
| Paper | Apparatus | Paper’s words |
|---|---|---|
| Johnston et al. 2025 | Maze Engineers Rotarod Instrument | “Rotarod testing was recorded utilizing Maze Engineers Rotarod Instrument (Skokie, IL, USA)” |
| Wen et al. 2024 | Accelerating rotarod IITC Life Science | “the accelerating rotarod (IITC Life Science, Woodland Hills, CA)” |
| Ahire et al. 2023 | Automated four‐lane rotarod tool | “Motor coordination was assessed using an automated four‐lane rotarod tool.” |
| Trabjerg et al. 2023 | Rotamex-5 Rota Rod Columbus Instruments | “Motor function was assessed using a rotarod (Rotamex-5 Rota Rod, Columbus Instruments, Columbus, Ohio, USA)” |
| Somebang et al. 2021 | Rotarod TSE Systems | “Rotarod (Hong et al., 2007, Hsieh et al., 2014, Liu et al., 2007, Raber et al., 2004, Suh et al., 2005) (TSE Systems)” |
| Trabjerg et al. 2021 | Rotamex-5 RotaRod Columbus Instruments | “Rotarod test (Rotamex-5 RotaRod, Columbus Instruments, Columbus, Ohio, USA)” |
| Drapeau et al. 2018 | Rotarod Omnitech Electronics Inc | “was assessed in the Rotarod test (Omnitech Electronics Inc)” |
| Xin et al. 2017 | Accelerating rotarod Softmaze, XR1514 | “The accelerating rotarod [35, 36] (Softmaze-XR1514, Shanghai, China) consisted of a felt-covered steel cylinder fitted to a rotating pump with a variable speed setting.” |
| Florez-Paz et al. 2016 | Rotarod Ugo Basile | “In the rotarod test (Ugo Basile), the mice were placed on a 5 cm diameter rotating cylinder along which they must walk in order not to fall off. The initial speed of rotation was 5 rpm and it accelerated to 20 rpm.” |
No apparatus named in Rattner et al. 2020.