ReplicateScience
TestsPapersMethodologyAboutOffline
Submit a paper
ReplicateScience

Records of how behavioral tests were run, taken from open-access papers. Built by ConductScience.

Browse

  • Tests
  • Papers
  • Scientists
  • Institutions

About

  • Methodology
  • About
  • Submit a paper
  • Offline edition
  • ConductScience

Legal

  • Privacy
  • Terms

© 2026 ConductScience. All rights reserved.

Papers/Rattner et al. 2020

Replicate Rattner et al. 2020

Developmental, cellular, and behavioral phenotypes in a mouse model of congenital hypoplasia of the dentate gyrus

Rattner A, Terrillion CE, Jou C, et al. eLife 2020;9:e62766.

Read the paper (doi:10.7554/elife.62766)Full text on PubMed Central (PMC7577738)Download the record as an RO-Crate
  • Animals

    Mice

  • Behavioral tests

    5

  • Test order

    Not found

  • Settings we look for

    10 of 18 missing

How to run it

Each step is a sentence from the paper’s Methods, word for word. This page covers the behavioral tests this site tracks, so the paper may have run others.

The test records were read once by AI and checked by code. No person has reviewed them yet. Code placed each sentence under its test from those records. How records are made

The tests

  • Y-maze testStore page for the Y Maze (opens the store in a new tab)
  • Morris water maze testStore page for the Morris Water Maze (opens the store in a new tab)
  • Elevated plus maze testStore page for the Elevated Plus Maze (opens the store in a new tab)
  • Open field testStore page for the Open Field Test (opens the store in a new tab)
  • Rotarod testStore page for the Rotarod (opens the store in a new tab)

The store is ConductScience, which runs this site. What it sells may differ from what the paper used.

We did not find the order of these tests in the Methods, so they appear here as the Methods list them.

Y-maze test

Compare with 7 other papers

What you need

  • Y-mazeSan Diego Instruments
  • Topscan tracking softwareCleversys
ConductScience sellsY Maze (opens the store in a new tab)
  1. The Y-maze consists of three 38 cm-long arms (San Diego Instruments).
  2. During the training phase, one arm of the Y-maze was blocked.
  3. The mouse was placed at the end of one of the two open arms and allowed to explore for 5 min.
  4. After a 30-min inter-trial interval, the test phase began: the blockade was removed, and the mouse was allowed to explore all three arms of the maze for 5 min.
  5. Distance traveled and time spent in each arm was automatically recorded using Topscan tracking software (Cleversys).
  6. Data from the first 2 min of the test phase were used to evaluate percent time spent in the novel arm.
Every setting as a table
SettingValuePaper’s words
Session duration
  • Training phase

    5 min

  • Test phase

    5 min

“The mouse was placed at the end of one of the two open arms and allowed to explore for 5 min”
“the test phase began: the blockade was removed, and the mouse was allowed to explore all three arms of the maze for 5 min”
Arm size
  • 38 cm-long

“The Y-maze consists of three 38 cm-long arms”
Other settings in the paper
Inter-trial interval

30-min

“After a 30-min inter-trial interval, the test phase began”
Arms

three

“The Y-maze consists of three 38 cm-long arms”
Blocked

Training phase

one arm

“During the training phase, one arm of the Y-maze was blocked”
The mouse was placed

Training phase

at the end of one of the two open arms

“The mouse was placed at the end of one of the two open arms”
Percent time spent in the novel arm

Test phase

first 2 min

“Data from the first 2 min of the test phase were used to evaluate percent time spent in the novel arm”
Experimenters

blind to the genotype

“During all behavioral testing, the experimenters were blind to the genotype”
Apparatus
Y-maze

San Diego Instruments

“The Y-maze consists of three 38 cm-long arms (San Diego Instruments)”
Topscan tracking software

Cleversys

“Distance traveled and time spent in each arm was automatically recorded using Topscan tracking software (Cleversys)”

Morris water maze test

Compare with 2 other papers

What you need

  • White tempera paint
  • Anymaze tracking softwareStoelting
  • Circular stainless-steel tank
  • Stainless-steel cylinder
  • Platform
ConductScience sellsMorris Water Maze (opens the store in a new tab)
  1. The Morris water maze test (MWM) was based on the protocol previously described in Pletnikov et al., 2008.
  2. The maze consisted of a circular stainless-steel tank 4 m in diameter filled with room temperature water made opaque with white tempera paint for the training, probe, and reversal trials.
  3. During the pretraining phase, a 10 cm platform was placed 1 cm below clear water in the center of a 2-m diameter stainless-steel cylinder in the MWM.
  4. For each mouse, the test protocol was as follows.
  5. The mouse was placed inside the perimeter of the cylinder and given 60 s to escape onto the visible platform throughout six trials in one day.
  6. During the hidden platform training phase, a 10 cm platform was placed in a fixed location in the maze, with the top of the platform hidden beneath 1 cm of water.
  7. The mouse was placed in the maze around the perimeter in one of four start positions in a semi-random fashion throughout six trials each day for three consecutive days.
  8. The mouse was allowed to search for the platform for 60 s, and, after finding the platform, to remain there for 15 s.
  9. Escape latency was recorded for each trial.
  10. 24 hr following the hidden platform training phase, the mouse was tested in one 60 s probe trial.
  11. Latency to cross into the platform area, number of crossings in the platform area, and time spent in the platform quadrant were measured using Anymaze tracking software (Stoelting).
  12. During the reversal phase, the hidden platform was placed in the MWM in a different quadrant from that used during the training phase.
  13. As in the training phase, the mouse was placed in the maze around the perimeter in one of four start positions in a semi-random fashion throughout six trials each day for two consecutive days.
  14. The mouse was allowed to search for the platform for 60 s and, after finding the platform, to remain there for 15 s.
  15. Path efficiency to the target was by calculating (i) the length of a straight line from the location where the mouse was placed in the tub to the platform, (ii) the distance that the mouse swam from its starting location to the first time it arrived at the platform (‘arrival’ being defined as the center of the mouse’s body crossing an 8 cm diameter circle centered on the platform), and (iii) the fraction consisting of the first value divided by the second value, giving a number between 0 and 1.

Cited to other work: Morris water maze protocol. Pletnikov et al., 2008.

Every setting as a table
SettingValuePaper’s words
Pool size
  • 4 m in diameter

“The maze consisted of a circular stainless-steel tank 4 m in diameter”
Water temperature
  • Training, probe, and reversal trials

    room temperature

“filled with room temperature water made opaque with white tempera paint for the training, probe, and reversal trials”
Platform size
  • Pretraining phase

    10 cm

  • Hidden platform training phase

    10 cm

“During the pretraining phase, a 10 cm platform was placed 1 cm below clear water”
“During the hidden platform training phase, a 10 cm platform was placed in a fixed location in the maze”
Platform depth below the surface
  • Pretraining phase

    1 cm

  • Hidden platform training phase

    1 cm

“During the pretraining phase, a 10 cm platform was placed 1 cm below clear water”
“with the top of the platform hidden beneath 1 cm of water”
Trial duration
  • Pretraining phase

    60 s

  • Hidden platform training phase

    60 s

  • Probe trial

    60 s

  • Reversal phase

    60 s

“given 60 s to escape onto the visible platform”
“The mouse was allowed to search for the platform for 60 s, and, after finding the platform”
“the mouse was tested in one 60 s probe trial”
“The mouse was allowed to search for the platform for 60 s and, after finding the platform”
Number of trials
  • Pretraining phase

    six trials

  • Hidden platform training phase

    six trials

  • Probe trial

    one

  • Reversal phase

    six trials

“throughout six trials in one day”
“throughout six trials each day for three consecutive days”
“the mouse was tested in one 60 s probe trial”
“throughout six trials each day for two consecutive days”
Other settings in the paper
Stainless-steel cylinder

Pretraining phase

2-m diameter

“in the center of a 2-m diameter stainless-steel cylinder in the MWM”
Following the hidden platform training phase

Probe trial

24 hr

“24 hr following the hidden platform training phase, the mouse was tested in one 60 s probe trial”
To remain there

Hidden platform training phase

15 s

“for 60 s, and, after finding the platform, to remain there for 15 s”
To remain there

Reversal phase

15 s

“for 60 s and, after finding the platform, to remain there for 15 s”
Start positions in a semi-random fashion

Hidden platform training phase

four

“in one of four start positions in a semi-random fashion throughout six trials each day for three consecutive days”
Start positions in a semi-random fashion

Reversal phase

four

“in one of four start positions in a semi-random fashion throughout six trials each day for two consecutive days”
The mouse was placed

Pretraining phase

inside the perimeter of the cylinder

“The mouse was placed inside the perimeter of the cylinder”
Day

Pretraining phase

one day

“throughout six trials in one day”
Consecutive days

Hidden platform training phase

three consecutive days

“throughout six trials each day for three consecutive days”
Consecutive days

Reversal phase

two consecutive days

“throughout six trials each day for two consecutive days”
Platform was placed

Pretraining phase

in the center of a 2-m diameter stainless-steel cylinder

“a 10 cm platform was placed 1 cm below clear water in the center of a 2-m diameter stainless-steel cylinder”
Platform was placed

Hidden platform training phase

in a fixed location in the maze

“a 10 cm platform was placed in a fixed location in the maze”
Platform was placed

Reversal phase

in a different quadrant from that used during the training phase

“the hidden platform was placed in the MWM in a different quadrant from that used during the training phase”
Water

Training, probe, and reversal trials

opaque with white tempera paint

“water made opaque with white tempera paint for the training, probe, and reversal trials”
Water

Pretraining phase

clear

“placed 1 cm below clear water”
Circle centered on the platform

8 cm diameter

“crossing an 8 cm diameter circle centered on the platform”
Experimenters

blind to the genotype

“During all behavioral testing, the experimenters were blind to the genotype”
Apparatus
White tempera paint
“water made opaque with white tempera paint”
Anymaze tracking software

Stoelting

“time spent in the platform quadrant were measured using Anymaze tracking software (Stoelting)”
Circular stainless-steel tank
“The maze consisted of a circular stainless-steel tank 4 m in diameter”
Stainless-steel cylinder
“in the center of a 2-m diameter stainless-steel cylinder in the MWM”
Platform
“a 10 cm platform was placed in a fixed location in the maze”
Methods cited to other work
Morris water maze protocol

Pletnikov et al., 2008

“The Morris water maze test (MWM) was based on the protocol previously described in Pletnikov et al., 2008”

Elevated plus maze test

Compare with 3 other papers

What you need

We found no named equipment for this test.

ConductScience sellsElevated Plus Maze (opens the store in a new tab)

The Methods give no steps of their own for this test.

Not in the Methods: Arm size, maze elevation, session duration and illumination.

Every setting as a table
SettingValuePaper’s words
Not in the MethodsArm size, maze elevation, session duration, illumination
Other settings in the paper
Experimenters

blind to the genotype

“During all behavioral testing, the experimenters were blind to the genotype”

Open field test

Compare with 10 other papers

What you need

We found no named equipment for this test.

ConductScience sellsOpen Field Test (opens the store in a new tab)

The Methods give no steps of their own for this test.

Not in the Methods: Arena size, session duration and illumination.

Every setting as a table
SettingValuePaper’s words
Not in the MethodsArena size, session duration, illumination
Other settings in the paper
Experimenters

blind to the genotype

“During all behavioral testing, the experimenters were blind to the genotype”

Rotarod test

Compare with 9 other papers

What you need

We found no named equipment for this test.

ConductScience sellsRotarod (opens the store in a new tab)

The Methods give no steps of their own for this test.

Not in the Methods: Rod speed, trial duration and number of trials.

Every setting as a table
SettingValuePaper’s words
Not in the MethodsRod speed, trial duration, number of trials
Other settings in the paper
Experimenters

blind to the genotype

“During all behavioral testing, the experimenters were blind to the genotype”

Quotes are shown under the paper’s CC BY license. Sentences are split into steps, and the words are unchanged.