CCR2 deficiency alters activation of microglia subsets in traumatic brain injury
Somebang K, Rudolph J, Imhof I, et al. Cell reports 2021;36(12):109727.
Animals
Mice
Behavioral tests
3
Test order
Not found
Settings we look for
6 of 12 missing
Each step is a sentence from the paper’s Methods, word for word. This page covers the behavioral tests this site tracks, so the paper may have run others.
The test records were read once by AI and checked by code. No person has reviewed them yet. Code placed each sentence under its test from those records. How records are made
We did not find the order of these tests in the Methods, so they appear here as the Methods list them.
Not in the Methods: Pool size, water temperature, platform size and platform depth below the surface.
Cited to other work: The cued platform version of the test as a whole; only citations follow the test name, with no wording such as "as described". Liu et al., 2007, Raber et al., 2004, Suh et al., 2005, Hong et al., 2007, Hsieh et al., 2014.
Cited to other work: Rank summary scores. Possin et al., 2016.
| Setting | Value | Paper’s words |
|---|---|---|
| Trial duration |
| “The maximum time per trial was 60 s.” |
| Number of trials |
| “three trials per session for two sessions in one day” |
| Not in the Methods | Pool size, water temperature, platform size, platform depth below the surface | |
| Other settings in the paper | ||
| Version | cued platform | “The cued platform version” |
| Post-TBI | 4 weeks | “starting at 4 weeks post-TBI” |
| Water | opaque | “filled with opaque water” |
| Platform | a cue on top | “A platform with a cue on top” |
| Sessions | two sessions in one day | “three trials per session for two sessions in one day” |
| A handler blinded to the animal group would guide the animal to the platform | after 60 s | “If an animal had not located the platform after 60 s, a handler blinded to the animal group would guide the animal to the platform.” |
| Apparatus | ||
| Swimming pool | Maze Engineers | “A swimming pool (Maze Engineers)” |
| Ethovision XT13 | Noldus, RRID:SCR_000441 | “Ethovision XT 13 | Noldus | RRID:SCR_000441” |
| Platform with a cue on top | “A platform with a cue on top was placed in opaque water.” | |
| Methods cited to other work | ||
| The cued platform version of the test as a whole; only citations follow the test name, with no wording such as "as described" | Liu et al., 2007, Raber et al., 2004, Suh et al., 2005, Hong et al., 2007, Hsieh et al., 2014 | “The cued platform version of the Morris Water Maze(Liu et al., 2007, Raber et al., 2004, Suh et al., 2005, Hong et al., 2007, Hsieh et al., 2014)” |
| Rank summary scores | Possin et al., 2016 | “Rank summary scores(Possin et al., 2016)” |
Not in the Methods: Illumination.
Cited to other work: The test as a whole; only citations follow the test name, with no wording such as "as described". Hong et al., 2007, Raber et al., 2004, Suh et al., 2005, Hsieh et al., 2014.
| Setting | Value | Paper’s words |
|---|---|---|
| Arena size |
| “inside a plexiglass enclosure (40 × 40 inches)” |
| Session duration |
| “Animals were tested for 10 min/day for two days.” |
| Not in the Methods | Illumination | |
| Other settings in the paper | ||
| Post-TBI | 3 weeks | “starting at 3 weeks post-TBI” |
| Animals were tested | two days | “Animals were tested for 10 min/day for two days.” |
| Apparatus | ||
| Plexiglass enclosure | “inside a plexiglass enclosure (40 × 40 inches)” | |
| Automated infrared photocells | “surrounded by automated infrared photocells” | |
| Computer | “connected to a computer with KinderScientific software” | |
| KinderScientific software | Hamilton & Kinder | “KinderScientific software (Hamilton & Kinder) to record data” |
| Methods cited to other work | ||
| The test as a whole; only citations follow the test name, with no wording such as "as described" | Hong et al., 2007, Raber et al., 2004, Suh et al., 2005, Hsieh et al., 2014 | “The open field test(Hong et al., 2007, Raber et al., 2004, Suh et al., 2005, Hsieh et al., 2014)” |
Not in the Methods: Trial duration.
Cited to other work: The test as a whole; only citations follow the test name, with no wording such as "as described". Hong et al., 2007, Hsieh et al., 2014, Liu et al., 2007, Raber et al., 2004, Suh et al., 2005.
| Setting | Value | Paper’s words |
|---|---|---|
| Rod speed |
| “a rotating rod that accelerated to 40 rpm over 300 s” |
| Number of trials |
| “Animals were assessed five trials/day for two days.” |
| Not in the Methods | Trial duration | |
| Other settings in the paper | ||
| Accelerated to 40 rpm over | 300 s | “a rotating rod that accelerated to 40 rpm over 300 s” |
| After TBI | three weeks | “three weeks after TBI” |
| Animals were assessed | two days | “Animals were assessed five trials/day for two days.” |
| Apparatus | ||
| Rotarod | TSE Systems | “Rotarod (Hong et al., 2007, Hsieh et al., 2014, Liu et al., 2007, Raber et al., 2004, Suh et al., 2005) (TSE Systems)” |
| Methods cited to other work | ||
| The test as a whole; only citations follow the test name, with no wording such as "as described" | Hong et al., 2007, Hsieh et al., 2014, Liu et al., 2007, Raber et al., 2004, Suh et al., 2005 | “Rotarod (Hong et al., 2007, Hsieh et al., 2014, Liu et al., 2007, Raber et al., 2004, Suh et al., 2005)” |
Quotes are shown under the paper’s CC BY license. Sentences are split into steps, and the words are unchanged.